How far each rafter size can span, by species, spacing and roof weight, from the IRC rafter table, and the smallest size for your span.

Rafter span

The largest horizontal span for each rafter size, and the smallest size for your span, from the IRC rafter span table for a 20 psf roof live load.

How it is worked out

The spans are read from IRC 2021 Table R802.4.1(2): roof live load 20 psf, ceiling attached to the rafters, deflection limit L/240, grade #2 lumber. The span is the horizontal projection of the rafter, measured from the inside of the wall plate to the ridge, not its sloped length. The table assumes ceiling joists or rafter ties at the bottom of the attic; with ties higher up, the code reduces the span (Table R802.4.1(9)). It does not cover snow: where the ground snow load is over 20 psf, other IRC tables apply.

How to use it

Pick the lumber species and grade stamped on the boards, the rafter spacing and the roof's dead load: 10 psf suits asphalt shingles on a light roof, 20 psf heavier roofing. Enter the horizontal span the rafter must cover, from the inside of the wall plate to the ridge. The calculator gives the smallest rafter that the table allows and the maximum span of every size. For the rafter's sloped length and cuts, use the rafter calculator.

Douglas fir-larch #2

SpacingDead load2x42x62x82x102x12
12 in10 psf9-1015-620-526-0over 26-0
12 in20 psf9-1014-718-522-626-0
16 in10 psf8-1114-118-522-626-0
16 in20 psf8-712-716-019-622-7
24 in10 psf7-1011-1115-118-521-4
24 in20 psf7-010-413-015-1118-6

Hem-fir #2

SpacingDead load2x42x62x82x102x12
12 in10 psf9-214-519-024-3over 26-0
12 in20 psf9-214-217-1121-1125-5
16 in10 psf8-413-117-321-1125-5
16 in20 psf8-412-315-618-1122-0
24 in10 psf7-311-514-817-1020-9
24 in20 psf6-1010-012-815-617-11

Southern pine #2

SpacingDead load2x42x62x82x102x12
12 in10 psf9-514-919-623-5over 26-0
12 in20 psf9-013-617-120-323-10
16 in10 psf8-713-517-120-323-10
16 in20 psf7-911-814-917-620-8
24 in10 psf6-19-211-713-916-2
24 in20 psf5-58-210-412-314-6

Spruce-pine-fir #2

SpacingDead load2x42x62x82x102x12
12 in10 psf9-514-919-624-10over 26-0
12 in20 psf9-514-418-222-325-9
16 in10 psf8-713-517-922-325-9
16 in20 psf8-612-515-919-322-4
24 in10 psf6-69-912-415-117-6
24 in20 psf5-118-811-013-615-7

Spans in feet and inches (horizontal projection). "Over 26-0" means the table gives no limit below 26 ft. Source: IRC 2021 Table R802.4.1(2), roof live load 20 psf, ceiling attached to rafters, L/240.

What the table assumes

Check with your building department

Rafters carry the roof, so a wrong size can fail under load. Most towns require a permit for new roof framing, and some adopt the IRC with changes. Roofs with valleys, hips, dormers, large openings, point loads or heavy tile need more than this table: use the full code tables or an engineer.

Code figures here are from the 2021 International Residential Code (IRC), which most US states and towns adopt, sometimes with changes. Check your local code and permit before you build, and use the span tables and an engineer for anything that carries a roof or floor load.